Stainless Steel Micro Small Pressure Sensor High Accuracy Pressure Load Cell Transducer

Product Details
Customization: Available
Type: Piezoresistive Pressure Sensor
Component: SemiConductor Type
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Years of Export Experience
The export experience of the supplier is more than 10 years
Full Customization
The supplier provides full customization services
Standardized quality control
The supplier has a complete and standardized quality control process, check the Audit Report for more information
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO45001:2018 certificate
ISO14001
to see all verified strength labels (28)
  • Stainless Steel Micro Small Pressure Sensor High Accuracy Pressure Load Cell Transducer
  • Stainless Steel Micro Small Pressure Sensor High Accuracy Pressure Load Cell Transducer
  • Stainless Steel Micro Small Pressure Sensor High Accuracy Pressure Load Cell Transducer
  • Stainless Steel Micro Small Pressure Sensor High Accuracy Pressure Load Cell Transducer
  • Stainless Steel Micro Small Pressure Sensor High Accuracy Pressure Load Cell Transducer
  • Stainless Steel Micro Small Pressure Sensor High Accuracy Pressure Load Cell Transducer
Find Similar Products

Basic Info.

Model NO.
HT15V
Output Signal Type
Analog Type
Production Process
Integration
Material
Stainless Steel
Thread Type
No
Wiring Type
Four-Wire
Measuring Medium
Gas and Liquid
IP Rating
IP65
Certification
RoHS
Customized
Customized
Keywords
Mini Sensor
Supply
5-10VDC
wire
13mm silicone wire
output
mv sigal
Transport Package
Carton
Specification
15mm
Trademark
HengTong
Origin
China
HS Code
9026209090
Production Capacity
50000PCS/Year

Packaging & Delivery

Package Size
6.40cm * 4.30cm * 3.80cm
Package Gross Weight
0.020kg

Product Description

Stainless Steel Micro Small Pressure Sensor High Accuracy Pressure Load Cell Transducer
Stainless Steel Micro Small pressure Sensor High Accuracy Pressure Load Cell
HT15V Silicon Piezoresistive Pressure Sensor


Introduction: 
HT15V is a silicon piezoresistive pressure sensor featuring a highly stable diffused silicon element core. It employs the piezoresistive effect of diffused silicon for precise measurement of both liquid and gas pressures. This sensor finds extensive usage in various applications, including air compressors and refrigeration systems .
Stainless Steel Micro Small Pressure Sensor High Accuracy Pressure Load Cell Transducer
Stainless Steel Micro Small Pressure Sensor High Accuracy Pressure Load Cell Transducer
Stainless Steel Micro Small Pressure Sensor High Accuracy Pressure Load Cell Transducer


Product  Features:
  1. Utilizes advanced technology and is encapsulated in a 316L stainless steel housing
  2. Wide measuring range 0~350KPa~60MpaS
  3. High reliability and excellent stability  
  4.  Constant voltage supply
Applications:
  1. Suitable for measuring non-corrosive gas and liquid pressure with 316L stainless steel compatibility
  2. Compact design, ideal for applications with limited space  
  3. Used in process control systems for monitoring and controlling pressure    
  4. Commonly used in refrigeration systems and air compressors for pressure measurement
Electrical performance:
  1. Power Supply: ≤10VDC
  2. Common Mode Voltage Output: 50% of the input (typical)
  3. Input Impedance:4KΩ~20KΩ
  4. Output Impedance:2.5KΩ~6KΩ
  5. Electrical Connection:100mm high-temperature wire,ribbon cable
Performance Parameters:
Measurement Range Gauge(G) 350KPa,1000KPa,2000Kpa
Absolute(A) 350KPaA,700KPaA,1000KPaA,2000KPaA
Sealed(S) 3500KPaS,7MPaS,10MPaS
  Typ Max Unit
NonLinearity   ±0.15 ±0.3 %F.S
Repeatability  0.05 0.1 %F.S
Hysteresis    0.05 0.1 %F.S
Zero Offset Output   0±1 0±2 mV
Full Scale Output   100±1 100±2 mV  
Zero Offset Temp. Drift   ±0.8 ±2 %F.S  
Full Scale Temp. Drift ±0.8 ±2 %F.S  
Compensated Temp. 0~70 ºC  
Operating Temperature   -20~80 ºC  
Storage Temperature  -40~125 ºC  
Allowable Overload Take the smaller value between 3 times the full scale or 80MPa    
Burst Pressure 5X the full scale    
Long-term Stability 0.2 %   F.S/Year  
Diaphragm Material 316L    
Insulation Resistance ≥200MΩ 100VDC    
Vibration No change under conditions of 10gRMS, 20Hz to 2000Hz    
Shock 100g,11ms    
Response Time ≤1ms    
O-ring Seal Nitrile rubber or Fluoro rubber    
Filling Medium Silicon Oil    
Weight ~20g    
The parameters are tested under the following conditions:  10V @25ºC  
 
Outline Construction
Dimension Stainless Steel Micro Small Pressure Sensor High Accuracy Pressure Load Cell Transducer
 
Electrical connection and compensation

Stainless Steel Micro Small Pressure Sensor High Accuracy Pressure Load Cell Transducer

 

 
Selection Examples
Stainless Steel Micro Small Pressure Sensor High Accuracy Pressure Load Cell Transducer
 
 
Ordering tips
1. Pay attention to the fit between the core size and the transmitter housing during assembly to achieve the         
required air tightness
2. During the assembly of the housing, ensure it is aligned vertically and apply even pressure to avoid jamming or damaging the compensation plate.
3. If the measured medium is not compatible with the core diaphragm and the housing material (316L), special instructions should be provided when placing the order.
4. Avoid pressing the sensor diaphragm with hands or sharp objects to prevent damage to the core due to diaphragm deformation or piercing.
5. Keep the pressure port of the gauge pressure core open to the atmosphere and prevent the entry of water, water vapor, or corrosive media into the core negative pressure chamber.
6. If there are any changes to the pin leads, follow the label on the actual core for reference.
 
company
 
Stainless Steel Micro Small Pressure Sensor High Accuracy Pressure Load Cell TransducerStainless Steel Micro Small Pressure Sensor High Accuracy Pressure Load Cell TransducerStainless Steel Micro Small Pressure Sensor High Accuracy Pressure Load Cell TransducerStainless Steel Micro Small Pressure Sensor High Accuracy Pressure Load Cell TransducerStainless Steel Micro Small Pressure Sensor High Accuracy Pressure Load Cell Transducer
 
Q&A
 
1.Q: What are the features of your pressure sensor transmitters?
   A: High precision, durability, and excellent performance. Customization available.
 
2.Q: Can I customize special specifications?
   A: Yes, our engineers can tailor products to meet specific needs. We provide OEM and ODM service
 
3.Q: What is your production capacity?
    A: Our manufacturing facilities can produce up to 30,000 pressure sensor transmitters per month, so we are fully capable of meeting the needs of large-scale orders. However, it is advisable to contact our sales team in advance to ensure smooth production and delivery scheduling
.
4.Q: What's the typical delivery period?
    A: 5~8 working day for standard models. Customized products may vary.
 
5.Q: How are the products priced? Any discounts?
    A: Competitive pricing with discounts for bulk orders or long-term partners
.
6.Q: What is the warranty of your products? And after-sales service?
    A: Our warranty time is 24 months after shipment, and our after-sales will respond with your questions in 24hrs, remote  instruction by PC network is always available.
 
 
 
 
 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier